Cube 2, 4 & 6 Zone Controller
Cube 2 |
|||
|
|||
FeaturesThe NEW Cube controller is a low-cost, easy to operate 2 zone controller designed for hot runner control applications. Despite this, the Cube contains a number of advanced features, including: -
|
|||
Technical Specification |
Value |
||
|
|
||
Size (mm) |
190 x 190 x 190 mm (w x d x h), (7.5 x 7.5 x 7.5 inches) |
||
Weight |
3.8 kg (8.4 lbs) |
||
Supply Voltage |
230 / 50 Hz Single Phase |
||
|
|
||
Number Of Zones |
2 |
Maximum Output Current |
10 Amps per zone, 15 Amps overall maximum |
Output Voltage |
220-240V ac |
||
Thermocouple Types Supported |
Type J (Fe/CuNi) or Type K (NiCr / NiAl) |
||
Control Accuracy |
+/- 0.5%. Updated every 100mS |
||
Calibration Accuracy |
<0.2 % Of Full Scale |
||
Display |
|
||
Type |
2 x 16 character LCD with permanent backlight—no automatic shutoff |
||
System Errors |
|||
Thermocouple |
Open, Reversed |
||
Heater |
Output fuse failure detection |
||
Support |
|||
Calibration Period |
Recommended every 12 Months |
||
Warranty |
2 Years (First year parts and labour, Second year labour only) |
||
Special Features |
|||
Bumpless Transfer |
Ramped increase in power when switching between Auto and Manual |
||
Bake Out |
Ramp to set point at 1% output power increase per second |
||
|
|
||
Product Code |
|||
Part Number |
Description |
||
CUBE2 |
2 Zone controller wired to UK / European 230V ac standard. ‘Harting’ 4-pin connectors for heater and thermocouple connection. |
||
Cube
4&6 |
|||
|
|||
FeaturesThe Cube 4 and 6 zone controller is a low-cost, easy to operate multi zone controller designed for hot runner control applications. Despite this, the Cube contains a number of advanced features, including: - • Automatic and Manual control of output power. • Soft Start ramp to set point to reduce temperature overshoot at set point. • Automatic load tuning—no manual intervention required to obtain accurate control. • Type J or Type K thermocouple input. • Interchangeable rear connector panel to accommodate different connector formats. • Simple 6 button operation, with automatic lockout for ease of operation. • Front panel indication of thermocouple failure and heater fuse failure. • Display errors for Open Thermocouple (OPEN), Reversed Thermocouple (REV) and Heater Open (COLD) • Recessed handles for ease of lifting • Rated up to 20A per zone • Internal high speed fusing for extra protection • 63A Mains isolation with individual switching for each pair of zones • Solid State Relays mounted on heat-sinks • Cooling fan fitted to increase life of internal components • Can be easily modified from 4—6 zones |
|||
Technical Specification |
Value |
||
|
|
||
Size (mm) |
575 x 380 x 225 mm (w x d x h) |
||
Weight |
19.25 kg |
||
Approvals |
CE |
||
Supply Voltage |
415 / 50 Hz Three Phase |
||
|
|
||
Number Of Zones |
4 or 6 |
Maximum Output Current |
20 Amps per zone |
Output Voltage |
220-240V ac |
||
Thermocouple Types Supported |
Type J (Fe/CuNi) or Type K (NiCr / NiAl) |
||
Control Accuracy |
+/- 0.5%. Updated every 100mS |
||
Calibration Accuracy |
<0.2 % Of Full Scale |
||
Display |
|
||
Type |
2 x 16 character LCD with permanent backlight—no automatic shutoff |
||
System Errors |
|||
Thermocouple |
Open, Reversed Indication On Display (OPEN, REV) |
||
Heater |
Output fuse failure detection, Heater Open Indication On Display (COLD) |
||
Support |
|||
Calibration Period |
Recommended every 12 Months |
||
Warranty |
2 Years (First year parts and labour, Second year labour only) |
||
Special Features |
|||
Bumpless Transfer |
Ramped increase in power when switching between Auto and Manual |
||
Bake Out |
Ramp to set point at 1% output power increase per 5 seconds |
||
|
|
||
Product Code |
|||
Part Number |
Description |
||
CUBE4 |
4 Zone controller wired to UK 415VAC standard. ‘Harting’ HBE16 pin connectors for heater and HA16 pin connector for thermocouple connection |
||
CUBE6 |
6 Zone controller wired to UK 415VAC standard. ‘Harting’ HBE16 pin connectors for heater and HA16 pin connector for thermocouple connection |
||
|